4 posts / 0 new
Last post
MichaelKopp
Offline
Last seen:5 years 10 months ago
加入:2014-10-13 12:55
Boot Loader -- details not found

Hi,

I did not find a precise description about the boot process of the DA14580. Some manuals say (e.g. that about booting via UART), that "A complete flow chart of the booting code is illustrated in the data sheet of the DA14580", but I could not find it in the "normal" data sheet (http://support.dialog-semiconductor.com/resource/da14580-datasheet). On the "Guide" link above, there is a link to the "full datasheet" (http://support.dialog-semiconductor.com/resource/da14580-full-datasheet), which does not work for me (error 404 -- and yes, I was logged in).

Could you please give me a document containing this flow chart and give me a list of the "magic numbers" recognized by the boot loader.

Thank you. Sincerely,
Michael

JE_Dialog
Offline
Last seen:1 month 1 week ago
工作人员
加入:2013-12-05 14:02
Hello Mikael, it would appear

Hello Mikael, it would appear that we haven't put the boot sequence into the datasheet - i 'm not sure why not . Let me get with marketing and provide you something here, please give me a couple of days : we will need to correct the datasheet but that will take time .

BR JE_Dialog

Update : a new version of AN-B-01 is in review which has all the boot sequence details you need. It is in for review on 17th so will be released shortly afterwards.

JE_Dialog
Offline
Last seen:1 month 1 week ago
工作人员
加入:2013-12-05 14:02
Hello Michael, the

Hello Michael, the application note has been updated to include the information you need.

BR JE_Dialog

MichaelKopp
Offline
Last seen:5 years 10 months ago
加入:2014-10-13 12:55
Hi,

Hi,
thank you for the diagram. It helps a lot...
Cheers,
Michael